search
arrow_back_iosSearch
search

Heater Burnout Alarm Detector - 12-segment load check

ID: JCKY002CustomizablePCBA
Supplier: Jacky Co.
For disconnection inspection and notification, it provides 12-segment load check and abnormal notification contacts for customers to install their own buzz or warning lights, immediately notifying the operator when the load is disconnected.
Interface: 4-20mA
Power: AC(220V±15% 50/60Hz)
Contact supplier for quote
for Customizable solution
Description
Specification
Supplier Info

Heater Burnout Alarm Detector—JK022VBC

Description

For disconnection inspection and notification, it checks whether the load is disconnected to maintain the best condition all the time. It provides 12-segment load check and abnormal notification contacts for customers to install their own buzz or warning lights, immediately notifying the operator when the load is disconnected.

The 12 LED indicator lights are the references for the load replacing. It can be applied to 3-phase thyristor power regulator, 3-phase solid state relay, single-phase thyristor power regulator, single-phase solid-state relay.

 

 

 

 

Features

l   12-segment LED inspection, when 12 LED bright over time through the Marquee, 12 LEDs are normal and standby.

l   12-segment of the load disconnection inspection and notification, 12-segment can be free to choose and match, for example: 2-segment or 6-segment for load inspection, there is no use to the part and turn off the DIP switch will not start inspect. Provide multi-segment DIP switch to the startup and shutdown of the disconnection inspect and notification function, with more different environments.

l   External LED indicator light, can be connected by cable to an extension of 1 ~ 2m, synchronization control panel 12 LED indicators light function can be connected via cable to conspicuous place on the equipment, such as the surface of the control box, the operation panel of the equipment, so that operating personnel can instantly grasp the equipment status.

l   Inspection and notification SCR power regulator, Inspection and notification SSR solid state relay.

l   By converter (Current Tansformer) and the thermometer mutual recognition, to determine whether the load is disconnected.

 

Specifications

Auxiliary voltage

AC 220V±15% 50/60Hz

Work frequency

50~60Hz ±5%

Models of choice

Inspect and notification of SCR power regulator, Inspect and notification SSR solid state relay (Order at the same time please inform the salesman)

Environment

-10°C~50°C Humidity Under 90% RH

Thermometer to receive the signal

4-20mA, 0-5V, 1-5V

SSR thermometer

ON-OFF

Function Specifications Options

  • Interface: 4-20mA
  • Power: AC(220V±15% 50/60Hz)
Heater Burnout Alarm Detector - 12-segment load check
Supplier:Jacky Co.
Location:Taichung, Taiwan
Contact supplier for quote
Contact supplier for quote